Instruction of Leeer-4T
Product Name: Time Mini UPS
Product Code: Leeer-4T
¡¡
Features:
¡ñ
World¡¯s first Mini UPS with individual backup time
¡ñ
Supply power for a fixed period
of time and then turn off automatically
¡ñ
Design for devices to select
their own time off (such as electronic game, slot machine, auto
shutdown after backup devices , regular alarm system, etc)
¡¡
Descriptions:
Set up a certain backup time according to requirement (for example
5¡±, 20¡±, 100¡±, 300¡±); the timing precision can be 1%.
Optional control AC power output with ON/OFF button
Lightest and smallest among the similar products
No limitation of minimum load wattage
Extended input voltage range
Optional output voltage
Environment friendly Ni-MH battery
LED and buzzer indicator (Optional)
Low/High-voltage protection
Overload protection
Output circle shortcut protection
Lighting protection
Build-in surge protection
Automatic shutdown when system failure
* Available choice - Combine with the function of Leeer-4M (Mobile
Mini UPS)
¡¡
Operation
instruction:
1 This unit must be fully charged before the first use. Connected
with an AC power socket for 10
hours
with the switch OFF, it will be charged automatically.
2 After charged, please install the unit between an AC power stock
and your devise with switch
ON. The
green LED indicates the Mini UPS is standby.
3 Once the AC power is cut off, the unit will support your devise to
work for the certain time as fixed,
and
then shutdown automatically.
4 If AC power is restored during the backup time, the unit will turn
into standby.
5 When the battery power is used up (even before the fixed turn-off
time), the unit will turn off into a
mode of
protection, please recharge it before the next use.
6 Please use this unit within suggested maximum level of voltage and
wattage. The unit performs
most
safely when the load wattage is below 60% of Rated Watts.
7 Resistive load is preferred. Please lower the load wattage when
it¡¯s capacitive or inductive
Technical Parameter:
|
Item |
Specification |
|
Rated Watts(W/VA) |
200W(330VA)
/
250W(410VA)
/
300W(500VA) |
|
Input |
Nominal Voltage |
65-265V-AC |
|
Frequency |
47-63Hz |
|
Output |
Nominal Voltage |
(
optional )100-265V-AC(¡À10%)X2 |
|
Frequency |
50/60Hz ¡À1Hz |
|
Transfer Time |
<10ms |
|
Output Control |
uto start when AC power off |
|
ABackup Time |
0.5-6000s¡À1% (depends on the load) |
|
Battery |
Nominal Voltage/ Capacity |
14.4V/1.2AH-2.4AH
(depend on the wattage of MINI UPS ) |
|
Charge Time |
10 hours (with the unit switched off) |
|
12-15 hours (with the unit switched on) |
|
Backup Time |
¡Ý5
minutes (Depends on the load) |
|
Type |
Ni-Cd or Ni-MH
(select according to the wattage of MINI UPS) |
|
Protection |
Low Voltage Protection of Battery |
11.0V(¡À1V) |
|
Reuse |
Restore via activation of AC |
|
Surge Protection |
Built-in surge protection |
|
High-voltage Protection |
Built-in high-voltage protection |
|
Low-voltage Protection |
Built-in low-voltage protection |
|
Lightning Protection |
Lightning protection |
|
Size(mm*mm*mm) |
195*142*45 |
|
Net Weight |
1.221kg for Leeer-4M-200W |
|
1.279kg for Leeer-4M-250W |
|
1.337kg for Leeer-4M-300W |
|
Operating Temperature |
-18¡æ
to 45¡æ |
|
Operating Relative Humidity |
10% to 95% |
¡¡
¡¡
¡¡
¡¡
¡¡
¡¡
¡¡
¡¡
¡¡
¡¡
¡¡
¡¡
¡¡
¡¡
¡¡
¡¡
|